STUDI PERENCANAAN GEDUNG BETON BERTULANG TAHAN GEMPA MENGGUNKAN ANALISIS ORDE DUA ELASTIS (ELASTIC SECOND ORDER ANALYSIS) (Studi Kasus : Gedung Laboratorium Terpadu Fakultas Teknik Universitas Jember)

Imam Baihaqi Krisna Bayu, Muhtar Muhtar, Pujo Priyono

Abstract


In the District of Jember, the last few years often happen earthquakes with a magnitude of medium. Therefore, the planning of high-rise buildings in the District of Jember have to take into account the earthquake forces, so that it can provide performance at least life safety. In doing a planning of earthquake resistant building should be an analysis of the structure in order to get the style that occurs on the elements of the structure. Analysis of the structure of itself has a lot of updates occur following the era of the development of the times, one analysis is the Analysis of the SecondOrder Elastic contained in the regulations of ACI 318-14. In the Analysis of the second Order Elastic version of ACI 318-14, the column must take into account the influence of the load is axial, the existence of the area of cracks on the entire length of the component structure of the column, so that for reinforced concrete columns are subjected to a fixed load, creep transfer most of the load from the concrete to the longitudinal reinforcement, load transfer this result to reinforcement press having a yielding prematurely, resulting in loss of EI as effective. Based on the data and the results of the calculation of the planning of the reinforcement of column using Analysis of second Order Elastic obtained extensive reinforcement (As) as follows , K2 = 1134,11 mm2, K3 = 2268,23 mm2, K4 = 13210,40 mm2, K5 = 5284,16 mm2, K6 = 13210,40 mm2.

Full Text:

PDF

References


ACI 318-14. Building Code Requirements For Structural Concrete. USANugroho, F. (2015). Jurnal Momentum ISSN : 1693-752X EVALUASI KINERJA BANGUNAN RENCANA GEDUNG HOTEL A . N . S DENGAN DILATASI ( MODEL B2 ) DI DAERAH RAWAN GEMPA Jurnal Momentum ISSN : 1693-752X. 17(2), 48–

IMRAN, I., & HENDRIK, F. (2016). Perencanaan Lanjut Struktur Beton Bertulang. Bandung: ITB PRESS.

Nugroho, F. (2015). Jurnal Momentum ISSN : 1693-752X EVALUASI KINERJA BANGUNAN RENCANA GEDUNG HOTEL A . N . S DENGAN DILATASI (MODEL B2 ) DI DAERAH RAWAN

GEMPA Jurnal Momentum ISSN : 1693-752X. 17(2), 48–57.

Palit, C. M., Pangouw, J. D., & Pandaleke, R. (2016). PERENCANAAN STRUKTUR GEDUNG HOTEL JALAN MARTADINATA MANADO. 4(4), 263–270.

Peraturan Pembebanan Indonesia Untuk Gedung (1983). Direktorat Penyelidikan Masalah Bangunan. Bandung

Pratiwi, G. A., Studi, P., Sipil, T., Indonesia, U. I., Studi, P., Sipil, T., & Indonesia, U. I. (2012). Analisis dan desain struktur beton bertingkat banyak berdasarkan perbandingan analisis

respons spektrum dan dinamik riwayat waktu. 281–293.

PRIYONO, P. (2019). buku ajar struktur beton tahan gempa. Jember: Pustaka Abadi.

Priyono, P. 2020. Diktat Kuliah Struktur Beton II. Berdasarkan SNI 2847-2013. Jember : Universitas Muhammadiyah Jember.

SNI 03-1726-2012. 2012. Tata Cara Perencanaan Ketahanan Gempa Untuk Struktur Bangunan Gedung Dan Non Gedung. Badan Standarisasi Nasional. Jakarta

SNI 03-2847-2013. 2013. Persyaratan Beton Struktural Untuk Bangunan Gedung. Badan Standarisasi Nasional. Jakarta.


Refbacks



Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
slot gacor slot gacor hari ini slot gacor 2025 demo slot pg slot gacor slot gacor